Home » Solar Store » Solar Gadgets » ASHAPOWER

Solar Gadgets By ASHAPOWER

ASHAPOWER MPPT Solar Charge Controller NEON 40HV Version 7.5 (12V/24V/36V/48V- 40Ampere) Auto voltage selection -Voc: 185V - Product Features
  • Compatible for 12V/24V/36V/48V Battery bank and The device gives a configurable charging current up to 40 Ampere (Voc: up to 185V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller HELIOS 50 Version 7.5 (48V/60V/72V/96V- 50Ampere) Auto voltage selection -Voc: 270V - Product Features
  • Compatible for 48V/60V/72V/96V Battery bank and The device gives a configurable charging current up to 50 Ampere (Voc: up to 270V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller SURYA 40HV Version 7.5 (12V/24V- 40Ampere) Auto voltage selection -Voc: 165V - Product Features
  • Compatible for 12V/24V Battery bank (Auto-Volatage Detection) and The device gives a configurable charging current up to 40 Ampere (Voc: up to 165V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller NEON 30LV Version 7.5 (12V/24V/36V/48V- 30Ampere) Auto voltage selection -Voc: 140V - Product Features
  • Compatible for 12V/24V/36V/48V Battery bank (Auto-Volatage Detection) and The device gives a configurable charging current up to 30 Ampere
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller NEON 80HV Version 7.5 (12/24/36/48V- 80Ampere) Auto voltage selection -Voc: 210V - Product Features
  • Compatible for 12V/24V/36V/48V Battery bank (Auto-Volatage Detection) and The device gives a configurable charging current up to 80 Ampere (Voc: up to 210V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER Solar MPPT Charge Controller (12V/24V : 50Amps : Max.Voc - 90V) Nova 50 Vers.7.6 - Product Features
  • Compatible for 12V/24V battery bank(Auto Selection)
  • Initial Limited Ampere Charging Feature for Long Back Up & Battery Life.
  • 4 stage smart charging for prolonged battery life (Bulk-Absorption-Float-Equalization), Programmable Initial limited ampere battery charging facility
  • Ultra-fast & efficient power point tracking(98.9%)
  • dsPIC33EP family micro controller based devices
  • MAXIMUM PANEL CAPACITY 1400W & VOC 90V
 
ASHAPOWER MPPT Solar Charge Controller APOLLO 40 Version 7.5 (24V/36V/48V/60V/72V- 40Ampere) Auto voltage selection -Voc: 230V - Product Features
  • Compatible for 24V/36V/48V/60V/72V Battery bank and The device gives a configurable charging current up to 40 Ampere (Voc: up to 230V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller SURYA 60HV Version 7.5 (12/24V- 60Ampere) Auto voltage selection -Voc: 165V - Product Features
  • Compatible for 12V/24V Battery bank and The device gives a configurable charging current up to 60 Ampere (Voc: up to 165V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller APOLLO 75 Version 7.5 (24V/36V/48V/60V/72V- 75Ampere) Auto voltage selection -Voc: 250V - Product Features
  • Compatible for 24V/36V/48V/60V/72V (Auto-Volatage Detection) Battery bank and The device gives a configurable charging current up to 75 Ampere (Voc: up to 250V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller HELIOS 60 Version 7.5 (48V/60V/72V/96V- 60Ampere) Auto voltage selection -Voc: 270V - Product Features
  • Compatible for 48V/60V/72V/96V Battery bank and The device gives a configurable charging current up to 60 Ampere (Voc: up to 270V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalization)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER Solar MPPT Charge Controller (48/60/72/96V : 50 Amp, Max.Voc:270V) Helios 50 Ver.7.5 - Product Features
  • Compatible for 48V/60V/72V/96V battery bank
  • Auto-detection and self setting of battery bank
  • 4 stage smart charging for prolonged battery life (Bulk-Absorption-Float-Equalization)
  • Ultra-fast & efficient power point tracking(98.9%)
  • dsPIC33EP family micro controller based devices
  • PV panel reverse polarity protection, Automatic disconnection of PV panels at night
  • Over voltage and overload protection from PV panels
 
ASHAPOWER MPPT Solar Charge Controller SURYA 40LV Version 7.5 (12V/24V- 40Ampere) Auto voltage selection -Voc: 140V - Product Features
  • Compatible for 12V/24V Battery bank (Auto-Volatage Detection) and The device gives a configurable charging current up to 40 Ampere (Voc: up to 140V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller SURYA 60LV Version 7.5 (12V/24V- 60Ampere) Auto voltage selection -Voc: 140V - Product Features
  • Compatible for 12V/24V Battery bank and The device gives a configurable charging current up to 60 Ampere (Voc: up to 140V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller APOLLO 60 Version 7.5 (24V/36V/48V/60V/72V- 60Ampere) Auto voltage selection -Voc: 230V - Product Features
  • Compatible for 24V/36V/48V/60V/72V Battery bank and The device gives a configurable charging current up to 60 Ampere (Voc: up to 230V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER NOVA 50 (12V/24V- 50 Ampere) MPPT Solar Charge Controller Version 7.6, Auto Voltage Selection -Voc: 90V - Product Features
  • Compatible for 12V/24V Battery bank (Auto-Volatage Detection) and The device gives a configurable charging current up to 50 Ampere (Voc: up to 90V)
  • The latest MPPT algorithm and dsPIC33EP family micro controller based program automatically tracks the maximum power point. The Maximum power point tracking efficiency is up to 98.9%, and conversion efficiency is 98.5%.
  • Provided 4 stage Smart charging for prolonged battery life. Under the maximum benefit of energy collection conditions (Bulk- Absorption- Float-Equalization)
  • 14 menu custom function settings and in-built manual settings keys and Programmable Initial limited ampere charging and periodic or voltage controlled equalization charging facility
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 
ASHAPOWER MPPT Solar Charge Controller NEON 80LV Version 7.5 (12V/24V/36V/48V- 80Ampere) Auto voltage selection -Voc: 165V - Product Features
  • Compatible for 12V/24V/36V/48V Battery bank and The device gives a configurable charging current up to 80 Ampere (Voc: up to 165V)
  • 4 stage Smart charging for prolonged battery life. (Bulk- Absorption- Float-Equalisation)
  • MULTIFUNCTION DISPLAY STATUS: E-today, Total Units, Battery voltage, Solar PV Module Ampere, Solar PV Module Voltage, Generating Power in Watts and Charging Ampere.
  • PROTECTIONS PROVIDED: Over voltage,over charging, overload and reverse polarity protection from PV panels
  • FORCED GRID TO SOLAR SHIFTING FEATURE: This feature helps converting a normal inverter to solar inverter) When connected battery voltage is at low level (after sunset or in dim sun light) a sudden heavy load connected on inverter drops the battery voltage below the preset solar to grid changeover volt and the charge controller shifts the connected inverter load to grid power. It will only be shifted back to solar mode automatically the very next day when battery is fully charged.
 


Facebook Twitter Instagram LinkedIn
© 2018 - BuyBestBrands.in All Rights Reserved
hit counter